70/950 Composite Flooring Systems
Features:
- Corrosion Resistance
- Long Lasting
Technical Drawing:
70/950 Maximum Load Capacity of Trapezoidal Form
Galvanized Sheet Thickness (mm) | |||||||||
Openness (m) | 0,70 | 0,80 | 0,90 | 1,00 | 1,10 | 1,20 | 1,30 | 1,40 | 1,50 |
1,00 | 2.466 | 2.814 | 3.161 | 3.507 | 3.852 | 4.196 | 4.539 | 4.881 | 5.222 |
1,50 | 1.096 | 1.251 | 1.405 | 1.559 | 1.712 | 1.865 | 2.017 | 2,169 | 2.321 |
2,00 | 617 | 704 | 790 | 877 | 963 | 1.049 | 1.135 | 1.220 | 1.305 |
2,50 | 395 | 450 | 506 | 561 | 616 | 671 | 726 | 781 | 835 |
3,00 | 274 | 313 | 351 | 390 | 428 | 466 | 504 | 542 | 580 |
- The tables are designed according to the method of safety stresses and EN 1993-1-3 (2006): Eurocode 3 Design of steel structures Part-1-3 Cold-formed steel.
- Steel yield strength was used as 220 N/mm² in the calculations.
- The loads in the tables are given as kg/m² and the values are given according to the multi-span continuous beam calculation.
- The tolerance values used in the calculations are given in accordance with TS EN 10143 Continuous Hot Dip Metal Coated Steel Strips and Plates-Size and Shape Tolerances Standard.
- The maximum deflection limit was loaded with L/200.